SU4000 AC Drives

This series AC Drives are sensorless vector control AC Drives and could be converted between Vector control and V/F control. Our AC Drives are programmed by PC tools by using MODBUS PROTOCOL through RS485. AC Drives >3.7KW are in metal cover.

1、INDIVIDUAL DATA SHEET

Type
Input
Voltage
MOTOR
G type / P type
(KW)
Output
Current
(A)
Power
(KW)
Drive Capacity(KVA)
Size:(mm)
SU405D5G07D7P43A Three phases  400V  50Hz
5.5/7.5
14/18
5.5/7.5
11/14
123*350*191
SU407D5G0011P43A Three phases  400V  50Hz
7.5/11
18/27
7.5/11
14/21
123*350*191
SU40011G0015P43A Three phases  400V  50Hz
11/15
27/34
11/15
21/26
153*453*217
SU40015G0018P43A Three phases  400V  50Hz
15/18.5
34/41
15/18.5
26/34
153*453*217
SU418D5G0022P43A Three phases  400V  50Hz
18.5/22
41/52
18.5/22
31/40
180*480*278
SU40022G0030P43A Three phases  400V  50Hz
22/30
52/65
22/30
40/50
180*480*278
SU40030G0037P43A Three phases  400V  50Hz
30/37
65/80
30/37
50/61
180*560*278
SU40037G0045P43A Three phases  400V  50Hz
37/45
80/96
37/45
61/73
180*560*278
SU40045G0055P43A Three phases  400V  50Hz
45/55
96/128
45/55
73/98
273*750*326
SU40055G0075P43A Three phases  400V  50Hz
55/75
128/165
55/75
98/130
273*750*326
SU40075G0090P43A Three phases  400V  50Hz
75/90
165/185
75/90
130/153
415*766*340
SU40090G0110P43A Three phases  400V  50Hz
90/110
185/224
90/110
153/170
415*766*340
SU40110G0132P43A Three phases  400V  50Hz
110/132
224/260
110/132
170/211
479*976*402
SU40132G0160P43A Three phases  400V  50Hz
132/160
260/302
132/160
211/230
479*976*402
SU40160G0185P43A Three phases  400V  50Hz
160/185
302/340
160/185
230/260
545*986*457
SU40185G0220P43A Three phases  400V  50Hz
185/220
340/450
185/220
260/340
545*986*457
SU40220G0250P43A Three phases  400V  50Hz
220/250
450/470
220/250
340/360
643*1231*494
SU40250G0280P43A Three phases  400V  50Hz
250/280
470/520
250/280
360/390
643*1231*494
SU40280G0315P43A Three phases  400V  50Hz
280/315
520/605
280/315
390/460
643*1231*494
SU40315G0350P43A Three phases  400V  50Hz
315/350
605/640
315/350
460/520
643*1231*494

2、TECHNICAL DATA

SERIES
SU4000
Input
Rated voltage frequency range
400V/50Hz/60Hz, voltage:+/-15%;frequency:+/-5% 200V/50Hz/60Hz, voltage:+/-15%;frequency:+/-5%
Output
Rated voltage
Three Phases: 200V
Three Phases: 400V
Control
characteristic
Control way
PWM Voltage Vector Control
Control mode
V/F Control / Sensorless Vector Control
frequency range
0.1 ~400Hz
Frequency precision
digital:±0.01%( -10℃~ +40℃ )
analogue:highest frequencyX 0.2%Hz ( 25℃ +/-10% )
Frequency setting
digital:0.01 Hz
analogue:highest frequency X 0.1%Hz
Output detinition
0.01 Hz
Over load capacity
general type:150% of rated output current per minute
exhaust fan,water pump:120% of rated output current per miniute
Frequency setting signal
0~+10V(20kΩ), 4~20mA(250Ω)
Speed up and down
0.0~3600second (setting speed up and down seperately)
Brake rotation moment
125%with braking resitance,20%without
V/f mode
15 presetting VF and programing VF
Protection
function
Overload protection
electronic overheat relay protection
Instantaneous over current flow
general typeG:250% of inverter rated current flow
exhaust fan,water pumpP: 200% of inverter rated current flow
Over load
general typeG:motor stops after 1 minute of 150%rated current flow exhaust fan,water pumpP:motor stops after 1minute of 120% rated current flow .
Over voltage
rectifier output 380V(200V grade)/760V(400V grade)
or lower,motor stops.
Low voltage
rectifier reduce output to 190V(200V grade)/380V(400V grade)or lower, motor stops.
Instantaneous power off
instantaneous power off over 15 ms or over, stop running it keep running when instantaneous power off less than 2 second.
Radiator overheat
thermal resistance protection.
Speedless protection
speedless protection during constant speed or speed up and down.
Grounding problem
protected by electronic circuit.
environment
Temperature humidity
-10℃~+40℃,90% relatively.
place
Indoor (avoid dust and corrosive gas).
elevation
below 1000 meters.
vibration
below 0.5G