This series AC Drives are sensorless vector control AC Drives and could be converted between Vector control and V/F control. Our AC Drives are programmed by PC tools by using MODBUS PROTOCOL through RS485. AC Drives >3.7KW are in metal cover.
![]() |
![]() |
---|
1、INDIVIDUAL DATA SHEET
Type
|
Input
Voltage
|
MOTOR
G type / P type
(KW)
|
Output
Current
(A)
|
Power
(KW)
|
Drive Capacity(KVA)
|
Size:(mm)
|
SU405D5G07D7P43A | Three phases 400V 50Hz |
5.5/7.5
|
14/18
|
5.5/7.5
|
11/14
|
123*350*191
|
SU407D5G0011P43A | Three phases 400V 50Hz |
7.5/11
|
18/27
|
7.5/11
|
14/21
|
123*350*191
|
SU40011G0015P43A | Three phases 400V 50Hz |
11/15
|
27/34
|
11/15
|
21/26
|
153*453*217
|
SU40015G0018P43A | Three phases 400V 50Hz |
15/18.5
|
34/41
|
15/18.5
|
26/34
|
153*453*217
|
SU418D5G0022P43A | Three phases 400V 50Hz |
18.5/22
|
41/52
|
18.5/22
|
31/40
|
180*480*278
|
SU40022G0030P43A | Three phases 400V 50Hz |
22/30
|
52/65
|
22/30
|
40/50
|
180*480*278
|
SU40030G0037P43A | Three phases 400V 50Hz |
30/37
|
65/80
|
30/37
|
50/61
|
180*560*278
|
SU40037G0045P43A | Three phases 400V 50Hz |
37/45
|
80/96
|
37/45
|
61/73
|
180*560*278
|
SU40045G0055P43A | Three phases 400V 50Hz |
45/55
|
96/128
|
45/55
|
73/98
|
273*750*326
|
SU40055G0075P43A | Three phases 400V 50Hz |
55/75
|
128/165
|
55/75
|
98/130
|
273*750*326
|
SU40075G0090P43A | Three phases 400V 50Hz |
75/90
|
165/185
|
75/90
|
130/153
|
415*766*340
|
SU40090G0110P43A | Three phases 400V 50Hz |
90/110
|
185/224
|
90/110
|
153/170
|
415*766*340
|
SU40110G0132P43A | Three phases 400V 50Hz |
110/132
|
224/260
|
110/132
|
170/211
|
479*976*402
|
SU40132G0160P43A | Three phases 400V 50Hz |
132/160
|
260/302
|
132/160
|
211/230
|
479*976*402
|
SU40160G0185P43A | Three phases 400V 50Hz |
160/185
|
302/340
|
160/185
|
230/260
|
545*986*457
|
SU40185G0220P43A | Three phases 400V 50Hz |
185/220
|
340/450
|
185/220
|
260/340
|
545*986*457
|
SU40220G0250P43A | Three phases 400V 50Hz |
220/250
|
450/470
|
220/250
|
340/360
|
643*1231*494
|
SU40250G0280P43A | Three phases 400V 50Hz |
250/280
|
470/520
|
250/280
|
360/390
|
643*1231*494
|
SU40280G0315P43A | Three phases 400V 50Hz |
280/315
|
520/605
|
280/315
|
390/460
|
643*1231*494
|
SU40315G0350P43A | Three phases 400V 50Hz |
315/350
|
605/640
|
315/350
|
460/520
|
643*1231*494
|
2、TECHNICAL DATA
SERIES
|
SU4000
|
|
Input
|
Rated voltage frequency range
|
400V/50Hz/60Hz, voltage:+/-15%;frequency:+/-5% 200V/50Hz/60Hz, voltage:+/-15%;frequency:+/-5% |
Output
|
Rated voltage
|
Three Phases: 200V
Three Phases: 400V
|
Control
characteristic
|
Control way
|
PWM Voltage Vector Control
|
Control mode
|
V/F Control / Sensorless Vector Control
|
|
frequency range
|
0.1 ~400Hz
|
|
Frequency precision
|
digital:±0.01%( -10℃~ +40℃ )
|
|
analogue:highest frequencyX 0.2%Hz ( 25℃ +/-10% )
|
||
Frequency setting
|
digital:0.01 Hz
|
|
analogue:highest frequency X 0.1%Hz
|
||
Output detinition
|
0.01 Hz
|
|
Over load capacity
|
general type:150% of rated output current per minute
exhaust fan,water pump:120% of rated output current per miniute
|
|
Frequency setting signal
|
0~+10V(20kΩ), 4~20mA(250Ω)
|
|
Speed up and down
|
0.0~3600second (setting speed up and down seperately)
|
|
Brake rotation moment
|
125%with braking resitance,20%without
|
|
V/f mode
|
15 presetting VF and programing VF
|
|
Protection
function
|
Overload protection
|
electronic overheat relay protection
|
Instantaneous over current flow
|
general typeG:250% of inverter rated current flow
exhaust fan,water pumpP: 200% of inverter rated current flow
|
|
Over load
|
general typeG:motor stops after 1 minute of 150%rated current flow exhaust fan,water pumpP:motor stops after 1minute of 120% rated current flow .
|
|
Over voltage
|
rectifier output 380V(200V grade)/760V(400V grade)
or lower,motor stops.
|
|
Low voltage
|
rectifier reduce output to 190V(200V grade)/380V(400V grade)or lower, motor stops.
|
|
Instantaneous power off
|
instantaneous power off over 15 ms or over, stop running it keep running when instantaneous power off less than 2 second.
|
|
Radiator overheat
|
thermal resistance protection.
|
|
Speedless protection
|
speedless protection during constant speed or speed up and down.
|
|
Grounding problem
|
protected by electronic circuit.
|
|
environment
|
Temperature humidity
|
-10℃~+40℃,90% relatively.
|
place
|
Indoor (avoid dust and corrosive gas).
|
|
elevation
|
below 1000 meters.
|
|
vibration
|
below 0.5G
|